  1. Catalog
  2. Armored cable
  3. VBShv

VBShv

1 - Sheath
2 - Armour of galvanized steel strips
3 -  Separation layer
4 - Insulation
5 - Conductor

DESCRIPTION

Power cable with insulated copper conductors with a separation layer of PVC compound and armour made of galvanized steel strips with a protective hose of PVC compound.

CONDUCTOR ACCORDING TO GOST 22483

1. Copper, single-wire, round-shaped, Class 1. Number of conductors: 1-5, cross-section: 1.5-16 sq. mm
2. Copper, multi-wire, round-shaped, Class 2. Number of conductors: 1-5, cross-section: 25-50 sq. mm
3. Copper, multi-wire, sector-shaped, Class 2. Number of conductors: 3-5, cross-section: 70-240 sq. mm

INSULATION AND SHEATH

VBShv

Insulation and sheath of polyvinyl chloride compound;

VBShvng(A)

Insulation of polyvinyl chloride compound;Sheath of low-combustible polyvinyl chloride compound.

VBShvng(A)-LS

Insulation and sheath of polyvinyl chloride compound with low fire danger and reduced smoke and gas emission.

VBShvng(A)-HL

Insulation of polyvinyl chloride compound; Sheath of low-combustible polyvinyl chloride compound with increased cold resistance.

VBShvng(A)-LSLTx

Insulation and sheath of polyvinyl chloride compound with low fire danger, reduced smoke and gas emission and low toxicity of combustion products

VBShvng(A)-LS-HL

Insulation and sheath of polyvinyl chloride compound with low fire danger,
with reduced smoke and gas emission and increased cold resistance.

APPLICATIONS

The cables are designed for transmission and distribution of electric power in stationary electrical installations with a rated alternating voltage of 0.66 and 1 kV of a rated frequency of 50Hz. The cables are designed for laying single cable lines in cable structures and premises. When laying such cables in groups, the use of fire protection means is mandatory. Cables with the -ng(A) and -ng(A)-HL indices are designed for group laying in cable structures of outdoor (open) electrical installations (overhead cable tray systems, cableways). Cables with the -ng(A)-LS and -ng(A)-LS-HL indices are designed for group laying of cable lines in cable structures and premises of indoor (closed) electrical installations, including at nuclear power facilities. For electrical wiring in residential and public buildings.